    Electrophoresis Genotype Machine
    Electrophoresis Genotype Machine

    Electrophoresis Genotype Machine in Nigeria by Scantrik Medical Supplies

    We are Nigeria’s No.1 Dealer, Wholesaler, Distributor and Supplier Store of Electrophoresis Genotype Machine with Best Price.

    Electrophoresis Genotype Machine

    Digital Electrophoresis Machine with Cell

    Laboratory Electrophoresis Machine

    electrophoresis machine Characteristic feature

    Type of Output: Constant-Voltage, Current

    Output range: 5~300V,1~300mA,maximum 90W

    Increment: 1V, 1mA

    Timer Range: 1min~9hr, 59min

    Display: LED

    Output jacks: Two sets of output jacks

    • Molding shell, touch keys, microprocessor intelligent control;

    • With automatic memory function;

    • With standard, timing operation function;

    • Automatic detection of no-load, over-load.

    basic technical specifications:

    Output direct voltage: 0~100V~200V~300V three range running adjustable

    Output direct current: 0~100mA

    Stability: <±1.5V. (This are the variable ranges of the output voltage as the power voltage variable ranges are 220V±22V or the output current variable ranges are 0~100mA.)

    Ripple voltage: <50mV

    Operating time: Can be working 8 hours continuously if the output current is 100mA

    Usage condition Environment temperature: 0~40℃, humidity:≤ 80%

    Usage power: 220V, 50Hz

    Consume power: About 60VA.

    Size: 355mm×220mm ×140mm

    Weight: About 6kg

     

    Basic accessories:

    Organic glass electrophoresis tank: 250mm × 160mm

    Output down lead: 1000mm × 2

    Power cable: 2000mm

    Power supply (structure and working principle of electrophoresis machines)

    This product adopts serial-type electronic stabilizing circuit,whose basic structure is as follows:

    Main circuit is a voltage doubling rectifying circuit made of silicon diode and electrolytic capacitor; BU4515 large power switch triode as pass element; 2M358 as comparison amplifier; sampling circuit made of output regulation potentiometer and divider resistance, with 2CW233 as reference voltage, to guarantee the stable output voltage of instruments.

    2. Uses

    Electrophoresis machines is an absolutely necessary machines for checking and analyzing in medical, scientific research and other test field. They can be used for filter paper, cellulose acetate electrophoresis.

    3. Instruction:

    The machines must be grounded and connected correctly according anode and cathode before the power on.

    Do not touch the electrodes and matter in the eletrophoresis tank in order to prevent from shocking during the power on. . Warni! The output end must not be shorted so as not to damage parts. When output short circuit happens or output current exceeds 100mA,the100mAfuse installed on circuit board inside machine will cut out and both voltmeter and ammeter show zero. When change fuse, please check if short circuit happens at output end. The machine can be started only when all faults have been cleared.

    Choose voltage value according your requirement.

    Turn on the power, and the indicator light. turn the adjustable voltage knob to obtain the appropriated output voltage value for eletrophoresis.